Min-Jun Kim, Young-Wook Jang, Yun-Ha Yoo, Jong-Jip Kim, Jung-Gu Kim김민준, 장영욱, 유윤하, 김종집, 김정구
Department of Advanced Materials Engineering, Sungkyunkwan University, Suwon 440-746, Korea
Korea Research Institute of Standards and Science, Daejeon 305-340, Korea성균관대학교 신소재공학부, 한국표준과학연구원
Effects of specimen area on the corrosion rate of low alloy steel were studied in sulfuric
acid solution. The corrosion behavior of specimen was tested by electrochemical impedance
spectroscopy (EIS), linear polarization resistance measurement (LPR) and p
Keyword : Electrochemical technique, Corrosion rate, Low alloy steel, Predominant corrosion region,
Specimen area